您现在的位置是:首页 >>product >>Pipeline pump >>ISG IRG IHG Vertical pipe pump
-
Pipeline pump is single suction a single-stage or multistage centrifugal pump, vertical structure, because of its import and export in a straight line, and import and export of diameter is the same, copy is like a pipe, hence the name anywhere can be installed in the pipeline for pipeline pump (pump). Structure features: for single suction single-stage centrifugal pump, the same import and export, and in a straight line, and shaft centerline into rectangular, a vertical pump.
Used in gas pipeline pressure is low, which is used to pressurization gas pressure, used to transport, biogas booster purposes. Flow of 0.3 cubic meters/min - 90 cubic meters/min
With an optional pressure. Model: DFL
Working voltage (V) : 220 V, 380 V
Frequency (Hz) : 50
Power (W) : 0.75 kw to 110 kw
Maximum pressure: 7.8 kpa - 78 kpa
Flow (m3 / min) : 0.3-90 (can choose different according to the needs of different flow rate and pressure)
The main features
Designed specifically for biogas booster pump. It can improve the phenomenon of gas pressure is insufficient, make biogas burning more fully, more firepower. Due to the effect of negative pressure of the pump, making the digester gas more fully, it is widely used in all kinds of pool and long-distance transmission of biogas.
Can be used for methane combustion pressure is low, low pressure pipelines.
The difference between the gas booster pump and other pump
Good air tightness: from the inlet to the outlet for strict air tightness test, no leakage.
Large flow, from 0.3 m3 / min to 90 cubic meters/min. You can choose different models according to need.
Long life: strictly separate pneumatic and electric circuit, will not affect the electrical life by gas moisture-laden air,
Good maintainability, with simple tools and accessories can repair themselves.
Explosion-proof motor
Pressure flow within a certain range can be adjusted
The working principle of
Biogas booster pump using the function of the two rotor squeeze each other, would carry out, low pressure gas in high pressure in the process of extrusion.
Use note editor
Run check: pipeline pump in power frequency (frequency) during normal operation, shall regularly check and record the ammeter, voltmeter, import and export pump group vacuum gauge, pressure gauge and flow meter meter readings. The vibration of the unit, such as noise, temperature rise is normal. The place should not have obvious fuel leak of the shaft sealing system.
Machines in use process there is always a problem, but as long as the good use machine and maintenance to ensure the best performance, in order to ensure the normal oil supply, the normal use of pipeline pump and rapid maintenance of oil depot equipment management has become a top priority task.